ATC Diversified ARA Series – Duplex, Triplexer, Quadraplexer

ARA series duplexers and quadraplexers from the ATC Diversified Electronics Division of Marsh Bellofram are designed for use in multiple load installations that are required to alternate in sequence while assuring equal run time on all loads. They also allow for additional loads to run in the event of excess load requirements, with the option of automatic or external clocking alterations.  When the factory installed jumper is in place, the alternating action is initiated by a control switch, which is common to one side of the control voltage. When the jumper is removed, alternating action is initiated by an isolated normally open switch.

 

**View the complete list of ATC Diversified Part Numbers carried by Universal Electronic Supply**

 

ARA Series Duplexers:
Used in control panel applications where two loads are required to alternate in order to provide equal run time. The alternating action is initiated by a control switch, which is common to one side of the control voltage. The output contacts will change states each time the control switch is opened, thus alternating the two loads. The LED indicators show the position of the output relay. The ARA series is the standard duplexer, providing automatic alternating sequence. The ARB series has the automatic sequencing feature plus the option of locking into a single sequence. A three position switch permits the field selection of normal duplexing action, locking in the A-B sequence, or B-A sequence, as required.

 

 

ARA-XXX-AFE Alternating Action
Triplexer: For automatic alterations, a factory-installed jumper is in place between terminals 3 and 4. The alternating action is accomplished when the control switch between terminals 2 and 4 opens. For external clocking alterations, the factory-installed jumper between terminals 3 and 4 is removed and replaced by an isolated normally open switch between terminals 2 and 3. The alternating action will occur each time this isolated switch is closed and then re-opened.

 

 

ARA-XXX-AGE
Quadraplexer:
For automatic alterations, a factory installed jumper is in place between terminals 11 and 12. The alternating action is accomplished when the control switch between terminals 2 and 3 opens.
For external clocking alterations, remove the factory-installed jumper between terminals 11 and 12 and place an isolated normally open switch between terminals 2 and 12. The alternating action will occur each time this isolated switch is closed and then re-opened. In the event of a power failure the Alternating Relays will return to their quiescent state and continue sequencing loads on one-at-a-time.